Ref. 1 - ECCS and ERS |
|
In the revised 1993 version of the 1983 report (ref. 2) of the European Community for Coal and Steel (ECCS) published in 1993 predicted values of lung indices were unchanged. They are almost universally applied in Europe. The 1993 report was officially adopted by the European Respiratory Society (ERS). The following chapter deals with spirometry, predicted values and bronchodilator responsiveness: Quanjer PhH, Tammeling GJ, Cotes JE, Pedersen OF, Peslin R, Yernault JC. Lung volumes and forced ventilatory flows. Eur Respir J 1993; 6 suppl. 16: 5-40. Erratum Eur Respir J 1995; 8: 1629. |
|
Ref. 2 - ECCS 1983 |
|
Quanjer PhH (ed.) Standardized lung function testing. Bull Eur Physiopathol Respir 1983; 19 suppl. 5: 45-51. |
|
Ref. 3 - Variability in patients |
|
Tweeddale PM, Alexander F, McHardy GJR. Short term variability in FEV1 and bronchodilator responsiveness in patients with obstructive ventilatory defects. Thorax 1987; 42: 487-490. |
|
Sourk RL, Nugent KM. Bronchodilator testing: confidence intervals derived from placebo inhalations. Am Rev Respir Dis 1983; 128: 153-157. |
|
Rozas CJ, Goldman AL. Daily spirometric variability. Normal subjects and subjects with chronic bronchitis with and without airflow obstruction. Arch Intern Med 1982; 142: 1287-1291. |
|
Ref. 4 - Literature on bronchodilatation |
|
Sourk RL, Nugent: Bronchodilator testing: confidence intervals derived from placebo inhalations. Am Rev Respir Dis 1983; 128: 153-157. |
|
Tweeddale PM, Alexander F, McHardy GJR. Short term variability in FEV1 and bronchodilator responsiveness in patients with obstructive ventilatory defects. Thorax 1987; 42: 487-490. |
|
Eliasson O, Degraff AC. The use of criteria for reversibility and obstruction to define patient groups for bronchodilator trials. Influence of clinical diagnosis, spirometric, and anthropometric variables. Am Rev Respir Dis 1985; 132: 858-864. |
|
Meslier N, Racineux JL. Tests of reversibility of airflow obstruction. Eur Respir Rev 1991; 1: 34-40. |
|
Quanjer PhH, Tammeling GJ, Cotes JE, Pedersen OF, Peslin R, Yernault JC. Lung volumes and forced ventilatory flows. Eur Respir J 1993; 6 suppl. 16: 5-40. Erratum Eur Respir J 1995; 8: 1629. |
|
Brand PLP, Quanjer PhH, Postma DS, Kerstjens HAM, Koëter GH, Dekhuyzen PNR, Sluiter HJ, Dutch CNSLD Study Group. Interpretation of bronchodilator response in patients with obstructive airway disease. Thorax 1992; 47: 429-436. |
|
Waalkens HJ, Merkus PJFM, van Essen-Zandvliet EEM, Brand PLP, Gerritsen J, Duiverman EJ, Kerrebijn KF, Knol K, Quanjer PhH. Dutch CNSLD Study Group. Assessment of bronchodilator response in children with asthma. Eur Respir J 1993; 6: 645-651. |
|
Casan P, Roca J, Sanchis J: Spirometric response to a bronchodialtor. Reference values for healthy children and adolescents. Bull Europ Physiopath Resp 1983; 19: 567-569. |
|
Pardos Martinez C, Fuertes Fernández-Espinar J, Nerín de la Puerta I, González Pérez-Yarza E: Cuándo se considera positivo el test de broncodilatación. Anales Españoles de Pediatria 2002; 57: 5-11. |
|
Dales RE, Spitzer WO, Tousignat P, Schechter M, Suissa S: Clinical interpretation of airway response to a bronchodilator. Epidemiologic considerations. Am Rev Respir Dis 1988; 138: 317-320. |
|
Ref. 5 - Isolated improvement in the VC |
|
Ramsdell JW, Tisi GM. Determination of bronchodilatation in the clinical pulmonary function laboratory: role of change in static lung volumes. Chest 1979; 76: 622-628. |
|
Girard WM, Light RW. Should the FVC be considered in evaluating response to bronchodilator? Chest 1983; 84: 87-89. |
|
Tweeddale PM, Alexander F, McHardy GJR. Short term variability in FEV1 and bronchodilator responsiveness in patients with obstructive ventilatory defects. Thorax 1987; 42: 487-490. |
|
Miller WF, Scacci R, Gast LR. Laboratory evaluation of pulmonary function (p. 276). JB Lippincott, Philadelphia, 1987. SBN 0-397-50574-4 |
|
Enright PL, Hyatt RE. Office spirometry (p. 191). Lea & Febiger, Philadelphia, 1987. ISBN 0-8121-1075-7 |
|
Berger R, Smith D. Acute postbronchodilator changes in pulmonary function parameters in patients with chronic airways obstruction. Chest 1988; 93: 541-546. |
|
Ref. 6 - Isolated increase in FVC: artifact? |
|
Berger R, Smith D. Acute postbronchodilator changes in pulmonary function parameters in patients with chronic airways obstruction. Chest 1988; 93: 541-546. |
|
Ref. 7 - Flow versus volume responders |
|
Woolcock AJ, Read J. Improvement in bronchial asthma not reflected in forced expiratory volume. Lancet 1965; 1323-1325. |
|
Ramsdell JW, Tisi GM. Determination of bronchodilation in the clinical pulmonary function laboratory. Role of changes in static lung volumes. Chest 1979; 76: 622-628. |
|
Paré PD, Lawson LM, Brooks LA. Patterns of response to inhaled bronchodilators in asthmatics. Am Rev Respir Dis 1983; 127: 680-685. |
|
|
Ref. 8 - Flow versus volume responders |
8 |
Pellegrino R, Viegi G, Brusasco V, et al. Interpretative strategies for lung function tests. ATS/ERS Task Force: Standardization of Lung Function Testing. Eur Respir J 2005; 26: 948-968. |